+86-21-5432 2103

PV Module Aging Test Location: 首页 > Product Solutions > PV Module Aging Test > Outdoor Comprehensive Performance Test System

Outdoor Comprehensive Performance Test System

Product description Specifications Download
Meet the temperature coefficient, NMOT (NOCT), outdoor exposure, hot spot test and power stability test requirements specified in 4.4, 4.5, 4.8, 4.9 and 4.19 clauses of IEC 61215:2016 standards. Meet the temperature test and hot spot test requirements specified in the MST20, MST21 clauses of the IEC61730-2016 standard. Meet the temperature test requirements specified in the 19 clause of the UL1703 standard.

Monitoring environmental parameters such as irradiance, ambient temperature, module  temperature, wind speed, and wind direction

Calculate the irradiation quantity

Open support using a metal blackboard to simulate boundary conditions

Intelligent automatically selecting the data according to IEC61215 and IEC61853, and automatically calculating the NMOT/NOCT data

Including MPPT electronic load with which the module could work at the maximum power point

Modular design, customers can choose different options according to their needs

Project

Parameters

Support Inclination

37±2.5℃或45±2.5℃

Irradiation range

 0~2000W/㎡

Irradiance accuracy

±5%

Temperature range

-50~200

Temperature accuracy

±1℃

Temperature repeatability

±0.5℃

Wind speed range

0~70m/s

Starting wind speed

≤0.25m/s

Wind direction range

0~360°

Wind direction resolution

15°

Acquisition frequency

Seconds/time

MPPT tracking accuracy

≥99.6%